Cold-morning Voc against the inverter's maximum, hot-day Vmp against its MPPT minimum, and the module range that fits.
Voc rises as cells get colder: module Voc × (1 + coefficient × (lowest temperature − 25 °C)). The most modules is the inverter's maximum DC voltage divided by that, rounded down. Vmp falls as cells heat up, so the fewest modules is the MPPT minimum divided by the hot Vmp, rounded up. 49.5 × (1 + -0.26% × (-3 − 25)) = 53.10 V
Figures from your module and inverter datasheets. Checked 21 October 2026. A check, not a design record: the design follows AS/NZS 5033 and the inverter maker's string sizing.
A module's voltage climbs as it gets colder, and it is highest at first light on the coldest morning of the year, when the cells are cold and the inverter has not started loading the string. That open-circuit voltage, summed along the string, must stay under the inverter's maximum DC input or the inverter can be damaged.
The other end matters too. On a hot afternoon the string's working voltage falls, and if it drops below the inverter's MPPT range the inverter loses output. The module count has to sit between the two.
Datasheet voltages are measured at standard test conditions, with the cells at 25 °C. The coefficient says how far the voltage moves for each degree away from that.
The lowest expected at the site, from long-term weather records, and note where the figure came from in your design record.
When the datasheet does not list a Vmp coefficient, the Pmax coefficient is a reasonable stand-in for the hot-day check, and errs on the low side.